LOGI CONTROL. Advanced mode 33
Cod. 523340
Rev. 10/1016
6.5. Modifying a program
6.5.1. Programming vectors
See the definition of the functions and values programmable in each phase in the following sections.
PHASE
EXECUTION
LEVEL
TEMP.
DISP.
ROTATION
ROTATION
TIME
COOL
DOWN
PAUSE
EXTRACT
EXTRACT
TIME
Ph
L
C / F
d
r
rt
c
rh
E
Et
1
Y / N
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...12
n.p.
n.p.
0 / 1
n.p.
2
Y / N
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...12
n.p.
n.p.
0 / 1
n.p.
3
Y / N
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...12
n.p.
n.p.
0...3
n.p. 2...4
4
Y
1…4
0 ... 90
32 ... 194
0, 1...4
1...3
1...20
0 / 1
n.p.
0...2
n.p. 2...4
5
Y / N
1…4
0 ... 60
32 ... 140
0, 1...4
1...3
1...12
n.p.
n.p.
1...3
n.p. 2...4
6
Y / N
1…4
n.p.
0, 1...4
1...3
1...12
n.p.
n.p.
1...3
n.p. 2...4
7
Y / N
1…4
n.p.
0, 1...4
1...3
1...12
n.p.
n.p.
1...3
n.p. 2...4
8
Y / N
1…4
n.p.
0, 1...4
1...3
1...12
n.p.
n.p.
1
n.p.
9
Y
1…4
0 ... 60
32 ... 140
0, 1...4
1...3
1...12
n.p.
0 / 1
1...6
n.p. 2...9
Note: (UK setting only). Program 3 cannot be modified.
6.5.2. Definition of phases
PHASES
DEFINITION
1, 2, 3
Soaking and pre-washes. Optional execution phase.
4
Washing. Obligatory execution phase.
5
First Rinse. Optional execution phase.
6 - 8
Second, third and fourth rinses. Optional execution phase.
9
Final Rinse. Obligatory execution phase.