Appendix
0020239562_02 EASICOM 3 Installation and maintenance instructions 33
Dia-
gnostics
code
Parameter
Values
Unit Increment, select, explanation
Default set-
ting
Own setting
Min. Max.
d.51 Correction of the max-
imum fan speed
-2500 0 rpm 1
Fan speed = Display value x 10
-1000 Adjustable
d.58 Solar circuit reheating 0 3 0 = Boiler's Legionella protection
function deactivated
3 = Hot water activated (min.
target value 60 °C)
0 Adjustable
d.60 Number of blocks by the
temperature limiter
Current value Not
adjustable
d.61 Number of unsuccessful
ignitions
Current value Not
adjustable
d.62 Night set-back 0 30 1 0 Adjustable
d.64 Average burner ignition
time
Current value s Not
adjustable
d.65 Maximum burner ignition
time
Current value s Not
adjustable
d.66 Activation of the warm
start function for hot wa-
ter
off = Function deactivated
on = Function activated
1 Adjustable
d.67 Remaining burner anti-
cycling time (setting un-
der d.02)
Current value min Not
adjustable
d.68 Number of unsuccessful
ignitions at 1st attempt
Current value Not
adjustable
d.69 Number of unsuccessful
ignitions at 2nd attempt
Current value Not
adjustable
d.70 Operation of the diverter
valve
0 2 0 = Normal operating mode
(DHW and heating mode)
1 = Mid-position (parallel opera-
tion)
2 = Permanent heating mode
position
0 Adjustable
d.71 Maximum heating flow
set target temperature
45 80 1 Section
"Technical
data"
Adjustable
d.73 Correction of the hot wa-
ter warm start temperat-
ure
-15 5 1 0 Adjustable
d.75 Maximum cylinder re-
heating time
20 90 min 1 45 Adjustable
d.77 Max. cylinder reheating kW 1
Section "Technical data"
Adjustable
d.80 Running time in heating
mode
Current value h Running time = Display value x
100
Not
adjustable
d.81 Running time in hot wa-
ter handling mode
Current value h Running time = Display value x
100
Not
adjustable
d.82 Number of burner igni-
tions in heating mode
Current value Number of ignitions = Display
value x 100
Not
adjustable
d.83 Number of burner igni-
tions in hot water hand-
ling mode
Current value Number of ignitions = Display
value x 100
Not
adjustable
d.84 Maintenance in 0 3000 h Number of hours = Display value
x 10
300 Not
adjustable
d.85 Increase in the min. out-
put (heating and hot wa-
ter handling mode)
kW 1 Adjustable
d.88 Flow rate limit value
for ignition in hot water
handling mode
0 1 0 = 1.7 l/min (no delay)
1 = 3.7 l/min (2 s delay)
0 Adjustable
d.90 Status of the eBUS room
thermostat
Current value off = Not connected
on = Connected
Not
adjustable

Table of Contents

Other manuals for Glow-worm Easicom 3 28c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Glow-worm Easicom 3 28c and is the answer not in the manual?

Glow-worm Easicom 3 28c Specifications

General IconGeneral
BrandGlow-worm
ModelEasicom 3 28c
CategoryBoiler
LanguageEnglish

Related product manuals