Notes on the documentation 2
0020239562_02 EASICOM 3 Installation and maintenance instructions 7
2 Notes on the documentation
2.1 Observing other applicable documents
▶ You must observe all the operating and installation in-
structions included with the system components.
2.2 Storing documents
▶ Pass these instructions and all other applicable docu-
ments on to the system operator.
2.3 Validity of the instructions
These instructions apply only to:
Product article number
Article number Gas Council Num-
ber
EASICOM 3 24c
0010021401 47-019-50
EASICOM 3 28c
0010021402 47-019-51
These products are only designed for natural gas systems.
2.4 Benchmark
Glow-worm is a licensed member of the Benchmark
Scheme.
Benchmark places responsibilities on both manufacturers
and installers. The purpose is to ensure that customers are
provided with the correct equipment for their needs, that it is
installed, commissioned and serviced in accordance with the
manufacturer’s instructions by a competent person approved
at the time by the Health and Safety Executive and that it
meets the requirements of the appropriate Building Regu-
lations. The Benchmark Checklist can be used to demon-
strate compliance with Building Regulations and should be
provided to the customer for future reference.
Installers are required to carry out installation, commission-
ing and servicing work in accordance with the Benchmark
Code of Practice which is available from the Heating and
Hotwater Industry Council who manage and promote the
Scheme.
Benchmark is managed and promoted by the Heating and
Hotwater Industry Council.
For more information visit www.centralheating.co.uk
3 Product description
3.1 Compartment Ventilation
The boilers are very high efficiency appliances.
As a consequence the heat loss from the appliance casing
during operation is very low.
Compartment ventilation is not required as the products are
only certified, and can only be fitted with a concentric flue
system.
3.2 Serial number
The serial number is located on the identification plate (1)
and in the short operating instructions (2) (→ Page 7).
Stickers showing the serial number are on the back of the
electronics box (3).
3.3 Information on the identification plate
The identification plate is mounted on the underside of the
product in the factory.
The identification plate keeps record of the country in which
the product is to be installed.
Information on the
identification plate
Meaning
Barcode with serial number
Serial number For quality control purposes; 3rd and 4th
digits = year of production
For quality control purposes; 5th and 6th
digits = week of production
For identification purposes; 7th to 16th
digits = product article number
For quality control purposes; 17th to 20th
digits = place of manufacture
Easicom 3 Product designation
XX, Gxx – xx mbar
(x kPa)
Gas group and gas connection pressure
as set at the factory
Cat. Approved gas category
Condensing techno-
logy
Efficiency of the boiler in accordance
with directive 92/42/EWG
Type: Xx3(x) Approved flue gas connections
PMS Maximum water pressure in heating
mode
PMW Maximum water pressure in hot water
handling mode
V/Hz Electric connection
W Max. electrical power consumption