Product dimensions
Range A B C D E F
Height Width Depth
Flue Outlet
position 1
Flue outlet
position 2
Ø80/125
Flue
diameter
Easicom
Easicom 24 (mm) 740 418 338 130 0
1
125
Easicom 28 (mm) 740 418 338 130 0
1
125
A
D
C
E
F
B
Easicom
Specications
Easicom specications - Combi
Easicom 24 28
Size
Casing dimensions (h w d)(mm) 740/418/338 740/418/338
Weight (li) 37kg 38kg
Performance
CH output (kW) Min/Max 7.7/18 8.8/23.3
DHW output (kW) Min/Max 8/24 9.3/28
DHW flow rate storage/combi (l/min. 35°C rise) 9.8 11.5
SEDBUK rating 2009 89.0 88.5
Nox class 5 (natural gas) Yes Yes
LPG Compatible Yes Yes
Construction
Main heat exchanger type Coiled tube Coiled tube
Heat exchanger material Stainless steel Stainless steel
Burner type Pre-mixed Pre-mixed
Fully modulating Yes Yes
DHW plate heat exchanger Yes Yes
Integrated hydrobloc Yes Yes
Installation
Suitable for sealed systems Yes Yes
Suitable for open-vent systems No No
Filling loop No No
Inbuilt automatic bypass Yes Yes
Inbuilt adjustable system bypass No No
Inbuilt condensate trap/siphon Trap Trap
Inbuilt boiler frost protection 2 stage 2 stage
Zero compartment ventilation Yes Yes
Clearances
Top (mm) (from top of boiler) 150 150
Side (mm) 0 0
Bottom (mm) 200 200
Front (mm)
2
600 600
User Interface
User display 2 digit LCD 2 digit LCD
Diagnostics Advanced Advanced
User adjustable CH temp control Yes Yes
User adjustable DHW temp control Yes Yes
Eco setting on DHW No No
Pre-tted analogue timer Yes Yes
Pipes
Pre-xing jig No No
Optional spacing frame No No
Water connections 2x22/2x15mm 2x22/2x15mm
Flues
Max horizontal ØØ60/100 6m 6m
Max vertical Ø60/100 6m 6m
Max horizontal Ø80/125 10m 10m
Max vertical Ø80/125 10m 10m
Optional plume management kit
Ø60/100
Yes Yes
Product clearances
Range A B C D E F G
Top flue Top Side Bottom Flue#1 Flue#2 Front
Easicom
Easicom 24 (mm) 150 5 0 200 5 5 600
2
Easicom 28 (mm) 150 5 0 200 5 5 600
2
Notes:
1 Flue is central to the boiler.
2 A removable compartment door can be placed at least
5mm in front of the appliance.
D
C
C
A B
G
E
F
Easicom
1110