Installation 5
0020200958_00 SUSTAIN ..r Installation and maintenance instructions 13
5.5.1.2 Vertical air/flue gas system
L
The openings in an attachment for separate lines must lead
to a 50 cm-sided square.
For each additional 90° elbow (or two 45° elbows) that is
required, the length (L) must be reduced by 1 m.
Length of the C33 type flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C33 type air/flue
pipe
C33 type air/flue
pipe
SUSTAIN 12r -A
(H-GB)
10 m 25 m
SUSTAIN 15r -A
(H-GB)
10 m 25 m
SUSTAIN 18r -A
(H-GB)
10 m 25 m
5.5.1.3 Air/flue gas system for header lines
L
The connections with the line are established using the ac-
cessory specially developed by the product manufacturer.
A boiler that is connected to a type C43 system must only be
connected to natural draught chimneys.
The condensate from header line systems must not drain
into the boiler.
For each additional 90° elbow (or two 45° elbows) that is
required, the length (L) must be reduced by 1 m.
Length of the C43 type flue pipe
Diameter of the air/flue pipe
Dia. 60/100 (L) Dia. 80/125 (L)
C43 type air/flue
pipe
C43 type air/flue
pipe
SUSTAIN 12r -A
(H-GB)
10 m 10 m
SUSTAIN 15r -A
(H-GB)
10 m 10 m
SUSTAIN 18r -A
(H-GB)
10 m 10 m
5.6 Electrical installation
Danger!
Risk of death from electric shock!
The mains connection terminals L and N re-
main live even if the product is switched off:
Switch off the power supply.
Secure the power supply against being
switched on again.
5.6.1 Opening the electronics box
A
B
B
Follow the instructions in the specified sequence.