Notes on the documentation 2
0020200958_00 SUSTAIN ..r Installation and maintenance instructions 7
2 Notes on the documentation
2.1 Observing other applicable documents
You must observe all the operating and installation in-
structions included with the system components.
2.2 Storing documents
Pass these instructions and all other applicable docu-
ments on to the system operator.
2.3 Applicability of the instructions
These instructions apply only to:
Product article number
Article number Gas Council
Number
SUSTAIN 12r -A (H-GB)
0010015891 41-019-39
SUSTAIN 15r -A (H-GB)
0010015892 41-019-40
SUSTAIN 18r -A (H-GB)
0010015893 41-019-41
3 Product description
3.1 Serial number
The serial number is located on a plate behind the front flap.
The plate is in a plastic fish plate. You can also display the
serial number in the display.
3.2 Information on the identification plate
The identification plate is mounted on the underside of the
product in the factory.
The identification plate keeps record of the country in which
the product is to be installed.
Information on the
identification plate
Meaning
Barcode with serial number
Serial number For quality control purposes; 3rd and 4th
digits = year of production
For quality control purposes; 5th and 6th
digits = week of production
For identification purposes; 7th to 16th
digits = product article number
For quality control purposes; 17th to 20th
digits = place of manufacture
SUSTAIN ..r Product description
2H, G20 - 20 mbar
(2 kPa)
Factory setting for type of gas and gas
connection pressure
Cat. Approved gas category
Condensing techno-
logy
Efficiency class of the boiler in accord-
ance with EC Directive 92/42/EEC
Type: Xx3(x) Permissible flue gas connections
PMS Maximum water pressure in heating
mode
PMW Maximum water pressure in hot water
handling mode
V/Hz Electric connection
Information on the
identification plate
Meaning
W Max. electrical power consumption
IP Level of protection
Heating mode
Hot water generation
Pn Nominal heat output range in heating
mode
Pnc Nominal heat output range in heating
mode (condensing technology)
P Nominal heat output range in hot water
handling mode
Qn Nominal heating load range in heating
mode
Qnw Nominal heating load range in hot water
handling mode
T
max.
Max. flow temperature
NOx NOx class for the product
Code (DSN) Specific product code
"CE label" section
Read the instructions.
"Recycling and disposal" section
GC no. Gas council number
3.3 CE label
The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.
The declaration of conformity can be viewed at the manufac-
turer's site.