Safety 1
5
Leave the building immediately and ensure
that others do not enter the building.
Notify the gas supply company or the
Emergency Service Provider
+44 (0) 800 111999 by telephone once you
are outside of the building.
1.4.2 Risk of death from escaping flue gas
If you operate the product with an empty con-
densate trap / siphon, then flue gas may es-
cape into the room air.
In order to operate the product, ensure that
the condensate trap / siphon is always full.
1.4.3 Risk of death due to blocked or
leaking flue gas routes
Installation errors, damage, tampering, imper-
missible installation sites or similar can cause
flue gas to escape and result in a risk of pois-
oning.
What to do if you smell flue gas in the prop-
erty:
Open all accessible doors and windows
fully to provide ventilation.
Switch off the product.
Check the flue gas routes in the product
and the flue gas diversions.
1.4.4 Risk of death from leaks if the
product is installed below ground
level
Liquid gas accumulates at floor level. If the
product is installed below ground level, liquid
gas may accumulate at floor level if there
are any leaks. In this case, there is a risk of
explosion.
Make sure that liquid gas cannot escape
from the product or the gas pipe under any
circumstances.
1.4.5 Risk of death due to explosive and
flammable materials
Do not use the product in storage rooms
that contain explosive or flammable sub-
stances (such as petrol, paper or paint).
1.4.6 Risk of death from electric shock
There is a risk of death from electric shock if
you touch live components.
Before commencing work on the product:
Unplug the mains plug.
Or disconnect the product from the power
supply by switching off all power supplies
(electrical partition with a contact gap of at
least 3 mm, e.g. fuse or circuit breaker).
Secure against being switched back on
again.
Wait for at least 3 minutes until the capa-
citors have discharged.
Check that there is no voltage.
1.4.7 Risk of death due to lack of safety
devices
The basic diagrams included in this docu-
ment do not show all safety devices required
for correct installation.
Install the necessary safety devices in the
installation.
Observe the applicable national and inter-
national laws, standards and directives.
1.4.8 Risk of poisoning and burns caused
by escaping hot flue gases
Only operate the product if the air/flue pipe
has been completely installed.
With the exception of short periods for
testing purposes, only operate the product
when the front casing is installed and
closed.
1.4.9 Risk of being burned or scalded by
hot components
Only carry out work on these components
once they have cooled down.
1.4.10 Risk of injury due to the heavy weight
of the product
Make sure that the product is transported
by at least two people.
1.4.11 Risk of corrosion damage due to
unsuitable combustion and room air
Sprays, solvents, chlorinated cleaning
agents, paint, adhesives, ammonia com-
pounds, dust or similar substances may lead
to corrosion on the product and in the flue
system.
0020283671_03 Energy 2 Installation and maintenance instructions