4.7 Adjusting The Gas Throttle
Each Glow T180 unit is factory set to operate with
Natural Gas or Liquid Propane. These units cannot
be eld converted.
When installing the water heater, it may be
necessary to adjust the throttle on the gas valve to
ensure a correct and efcient operation.
This can be done by inserting a 2 mm allen key
into the throttle adjustment screw on the gas valve.
Turning this screw right or left will change the CO
2
value measured by the combustion analyzer. See
Figure 4.3 for the throttle adjustment locations.
Figure 4.2 - Throttle adjustments
Figure 4.3 - Throttle adjustment locations
MANIFOLD PRESSURE
TEST PORT
LINE
PRESSURE
TEST PORT
TROTTLE
ADJUSTMENT SCREW
WITH A
ADJUST CO
2
% BY ROTATING THROTTLE ADJUSTMENT SCREW
5/64 (2mm) ALLEN
KEY OR FLAT HEAD SCREW DRIVER
GAS VALVE
VENTURI
DO NOT
ADJUST
Throttle Adjustment
Turn adjustment screw
clockwise to decrease
CO
2
value
Turn adjustment screw
counter clockwiase to
increase CO
2
value
NOTE:
The unit should be operating at maximum capacity for 5 minutes prior to adjusting the throttle.