Glow T180
Tankless Condensing Water Heater
60
7.3 Flue Gas Temperature Exceeds The Limit
A16
FLUE GAS TEMPERATURE EXCEEDS
THE LIMIT (65degC/150degF)
CHECK THE EXHAUST VENT
IS IT CLEAR FROM
OBSTRUCTIONS?
CLEAR ALL OBSTACLES
INSIDE VENT AND FROM
VENT TERMINAL
NO
IF UTILIZED FOR SPACE
HEAT AND/OR IN ECO OR
COMFORT MODE CHECK TO
ENSURE SET POINT IS
63degC/145degF OR BELOW
YES YES
NO
REDUCE TEMPERATURE SET POINT
RESET HEATER
RESET HEATER
VERIFY TEMPERATURE
VERIFY TEMPERATURE
DHW Set point cannot be set higher than
145°F/63°C for space heating applications.