SmartBox
®
4 / SmartBox
®
4 PRO
part no. 28 400 57 d 17 / 28
height
Entry option for the reference height for the 2-
point measurement, for other probe measurement
range or for an unknown density. Subtract 1.0cm
from the actual measured level and enter this
Calibrate:Yes
If activated (Yes), the display in menu steps
“1.Measure probe” and “2.Liquid” is then "by
Calibration". If this is entered with an
almost empty tank, it is recommended that you
make a correction the next time it is filled.
Press [Enter] to return to display mode
m³
%
m
kg
IG
UG
t
mbar
cubic meters:
percent:
meter:
kilogram:
imperial Gallon:
US liquid gallon:
ton:
millibar:
2.50m³
99.50%
2.50m
999900kg
219750IG
263900UG
2.50t
500mbar
Without rounding
20L
50L
100L
200L
500L
minimal increments
Rounding increments in relation to the set volume
set with [+] / [-] keys
Press [Enter] to return to display mode
Send a test SMS to #T (modem must be logged
on)
tanks
with
SmartBox 4
Delete the registered Tank n (Tank 2, 3, 4)
Replace Tank 2 for Tank 3
Replace Tank 2 for Tank 4
Replace Tank 3 for Tank 4
tanks
with
SmartBox
Settings for tank n are deleted and reset to
default settings (tanks 2, 3, 4)