SmartBox
®
4 / SmartBox
®
4 PRO
part no. 28 400 57 d 17 / 28
Menu
Setting
Description
10.Trim
height
xxx.x cm
Entry option for the reference height for the 2-
point measurement, for other probe measurement
range or for an unknown density. Subtract 1.0cm
from the actual measured level and enter this
value.
Calibrate:No
Calibrate:Yes
If activated (Yes), the display in menu steps
“1.Measure probe” and “2.Liquid” is then "by
Calibration". If this is entered with an
almost empty tank, it is recommended that you
make a correction the next time it is filled.
11.Exit
Press [Enter] to return to display mode
12.Unit
L default setting
%
m
kg
IG
UG
t
mbar
kPa
liter:
cubic meters:
percent:
meter:
kilogram:
imperial Gallon:
US liquid gallon:
ton:
millibar:
kilopascals:
999900L
2.50m³
99.50%
2.50m
999900kg
219750IG
263900UG
2.50t
500mbar
50kPa
Menu
Setting
Description
13.Rounding
Automatically
Without rounding
20L
50L
100L
200L
500L
1.000L
Default settings
minimal increments
Rounding increments in relation to the set volume
set with [+] / [-] keys
14.Exit
Press [Enter] to return to display mode
15.Modem
Active: Yes/No
Selection
Send an SMS:
No/Yes
Send a test SMS to #T (modem must be logged
on)
16.Sort
tanks
with
SmartBox 4
ESC
Exit the menu
Delete Tank n
Delete the registered Tank n (Tank 2, 3, 4)
T2<->T3
Replace Tank 2 for Tank 3
T2<->T4
Replace Tank 2 for Tank 4
T3<->T4
Replace Tank 3 for Tank 4
16.Sort
tanks
with
SmartBox
4 PRO
ESC
Exit the menu
Delete Tank n
Settings for tank n are deleted and reset to
default settings (tanks 2, 3, 4)