10 Technical Parameters
41
User Manual V1.0-2022-12-15
Nominal Output Apparent Power (VA)
*4
5000 6000
Max. AC Active Power (W) 5000 6000
Max. AC Apparent Power (VA) 5000 6000
Nominal Power at 40℃ (W)(For Brazil only) 5000 6000
Max Power at 40℃ (including AC overload)(W)(For
Brazil only)
5000 6000
Nominal Output Voltage (V) 220 220
Nominal AC Grid Frequency (Hz) 60 60
Max. Output Current (A) 22.8 27.3
Max. Output Fault Current (Peak and Duration) (A) 35 35
Inrush Current (Peak and Duration) (A) 60 80
Nominal Output Current (A) 22.7 27.3
Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic Distortion <3% <3%
Maximum Output Overcurrent Protection (A) 42 50
Eciency
Max. Eciency 97.8% 97.8%
European Eciency 97.5% 97.5%
Protection
PV String Current Monitoring Integrated
PV Insulation Resistance Detection Integrated
Residual Current Monitoring Integrated
PV Reverse Polarity Protection Integrated
Anti-islanding Protection Integrated
AC Overcurrent Protection Integrated
AC Short Circuit Protection Integrated
AC Overvoltage Protection Integrated
DC Switch Optional
DC Surge Protection Type III
AC Surge Protection Type III
AFCI Optional
Remote Shutdown Optional
General Data
Operating Temperature Range (℃) -25 - +60
Relative Humidity 0 - 100%
Max. Operating Altitude (m)
*5
4000