34
08 System Commissioning
User Manual V1.0-2022-10-30
Parameters Description
Ver Check the software version.
Set Language Set language accordingly. Languages: English, Portuguese, Spanish.
Set Time
Set time according to the actual time in the country/region where the
inverter is located.
W/L Reset Power o and restart the WiFi module.
W/L Reload
Restore the factory settings of the WiFi module. Recongure the WiFi
module network parameters after restoring the factory settings,
PF Adjust Set the power factor of the inverter according to actual situation.
Time Interval Set Time Interval according to actual needs.
Shadow MPPT Enable the shadow scan function if the PV panels are shadowed.
Power Limit
Soft limit: Set the power feed into the utility grid according to local
requirements and standards.
Hard limit: The inverter and the utility grid will automatically disconnect
when the power feeds into the grid excesses the required limit.
Set Power Limit
Set the power feed back into the utility grid according to the actual
situation.
Set Calibrate
Addr
Set the actual Modbus address.