09 Maintenance
9.5 Routine Maintenance
Maintaining Item Maintaining Method Maintaining Period
System Clean
Check the heat sink, air intake, and air
outlet for foreign matter or dust.
Once 6-12 months
DC Switch
Turn the DC switch on and o ten
consecutive times to make sure that it is
working properly.
Once a year
Electrical Connection
Check whether the cables are securely
connected. Check whether the cables are
broken or whether there is any exposed
copper core.
Once 6-12 months
Sealing
Check whether all the terminals and ports
are properly sealed. Reseal the cable hole
if it is not sealed or too big.
Once a year
WARNING
Make sure that the inverter is powered o.
Wear proper PPE before any operations.

Other manuals for Goodwe MS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe MS Series and is the answer not in the manual?

Goodwe MS Series Specifications

General IconGeneral
Power Range3-10 kW
MPPT2
AC Voltage Range180-280 V
Protection LevelIP65
Cooling MethodNatural convection
ModelMS Series
Rated Output Current34.8 A
Operating Temperature Range-25°C to 60°C
CommunicationWi-Fi / Ethernet