Error messages
Action when an error occurs:
1. Alarm output A1 is activated; configuration digit Alarms 1 defines its action (see Configuration, page 20).
2. LED A1 flashes on all levels. Errors are only displayed (flashing) on the operating level: With incorrect measured values on the display which other-
wise shows the correct value (SE H, SE L, CE and YE), the other errors are shown on the upper display.
3. During parameter setting and/or configuration, the operating level is entered 10 s after the value setting is ended.
4. See the following table for exceptions and more information.
Display Error source Reaction Remedy
sensor error high
Sensor breakage or
actual value > upper range limit
1
sensor error low
Polarity of sensor or
actual value < lower range limit
current error
Wrong polarity of current transformer,
transformer not suited or unserviceable
Same as heating current monitor alarm
Continues to control
2
y error
Position readback message beyond
calibration; Y100
Y0
No reaction to error 3
Controller
type
Regulation ratio output
2-, 3-state
YSE = 100/0/100% YSE 100/0/100%
100/0/100%
If controller in stable condition:
Last "plausible" regulation
ratio, if not: YSE
Step
YSE
Limit signal
Positioner
No reaction to error