Setup
3A1782D 13
5. Make sure the power switch is OFF and the sprayer
is unplugged.
6. Separate prime tube (smaller) from suction tube
(larger).
7. Place prime tube in waste pail.
8. Submerge suction tube in water or flushing solvent.
9. Move Prime/Spray Valve to PRIME.
10. Plug sprayer in a grounded outlet.
11. Push pump priming button two times.
12. Turn power switch ON.
13. Align setting indicator with Prime/Clean setting on
Pressure Control knob until pump starts, page 11.
14. When sprayer starts pumping, flushing solvent and
air bubbles will be purged from system. Allow fluid
to flow out of prime tube, into waste pail, for 30 to 60
seconds.
15. Turn power switch OFF.
16. Transfer suction tube to paint pail and submerge
suction tube in paint.
17. Turn power switch ON.