Start Up
3A6342A 21
5. Make certain the Pressure Control
Knob is set to OFF (all the way
counterclockwise).
6. Plug power cord into a properly
grounded electrical outlet.
7. Turn ON/OFF switch to ON position.
8. Turn Pressure Control Knob to
Prime/Slow in order to start the motor.
Flushing fluid will flow up the Suction
Tube and out the Drain Tube into the
waste pail.
9. When you see flushing fluid exiting the
Drain Tube, turn Pressure Control Knob
to FastFlush setting and allow unit to
flush for 30-60 seconds.
10. Turn the ON/OFF switch to OFF
position.
Strain the Paint
Disposable paint strainer bags are used to
remove coarse particles and debris from
new or previously opened paint or stain, and
are available where paint is sold. To avoid
priming problems and Spray Tip clogs it is
recommended to strain all paints and stains
before spraying. Stretch a disposable paint
strainer bag over a clean pail and pour the
paint through the strainer.
Fill Pump (Prime Pump)
The Prime/Spray Valve directs the fluid to
either the Drain Tube or the Hose and Spray
Gun. It is used to prime the sprayer, which
means to evacuate the air out of the pump,
Hose, and Spray Gun.
Your Spray Gun will not spray if there is air in
the system. It is necessary to prime the pump,
Hose, and Spray Gun any time air enters the
Suction Tube.
High-pressure spray is able to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.
ti26894a