Cleanup
3A6342A 27
Cleanup
1. Perform Pressure Relief Procedure,
page 19.
2. Remove Spray Tip Guard and Spray Tip.
For additional information, see separate
Spray Gun manual.
Clean Drain Tube
3. Remove Suction Tube and Drain Tube
from paint; wipe excess paint off outside
of Suction Tube.
4. Place Suction Tube in appropriate
flushing fluid. Place Drain Tube in waste
pail.
5. To flush Drain Tube and pump turn
Prime/Spray Valve down to PRIME
position.
6. Turn pressure control to Prime/Slow and
turn ON/OFF switch to ON position to
start the motor. Flushing fluid will flow up
the Suction Tube and out the Drain Tube
into the waste pail. Allow flushing fluid to
flow out of Drain Tube for 5 seconds.
7. Turn Pressure Control Knob to OFF
setting (all the way counterclockwise).
Clean Hose and Spray Gun
8. Hold Spray Gun against a grounded
metal waste pail. Point Spray Gun into
waste pail.
ti24592a