Troubleshooting
3A6342A 45
• Sprayer does not run at all
• LED Display shows CODE 16
• BlueLink status light blinks 16
times repeatedly
Motor position
sensor not
working
1. Set sprayer to OFF and
disconnect power to sprayer.
2. Remove motor cover.
3. Disconnect motor position sensor
and inspect for damage at con-
nectors.
4. Reconnect sensor.
5. Turn power ON. If code contin-
ues, replace motor.
• Sprayer does not run at all
• Display shows CODE 17
• BlueLink status light blinks 17
times repeatedly
Sprayer
plugged into
wrong voltage
1. Set sprayer to OFF and
disconnect power to sprayer.
2. Locate a good voltage supply to
avoid damage to electronics.
Problem Cause Solution