Repair
Replace Replace
Replace
Fluid Fluid
Fluid
Inlet Inlet
Inlet
Sensor Sensor
Sensor
SeeFluidInletSensorKit17F837manual3A3009.
1.Flush.SeeFlushing,page50.
2.SeeShutdown,page49.
3.Disconnectinletsensorcablefromthe󰘱uidinlet
assembly.Inspectcablefordamageandreplace
ifnecessary.SeeElectricalSchematics,page94.
Figure6FluidInletSensor
4.Toreplacesensorcable:
a.CutanywiretiesanddisconnectfromHCM.
SeeElectricalSchematics,page94.
NOTICE NOTICE
NOTICE
Topreventdamagetocable,securecablewith
wireties.
5.Replacesensorandsecurewithwireties.
Replace Replace
Replace
Pressure Pressure
Pressure
Transducers Transducers
Transducers
1.Flush.SeeFlushing,page50.
2.SeeShutdown,page49.
3.Disconnecttransducercables(405)from#6and
#7connectorsontheHCM.
4.Removewiretiesconstrainingtransducercable
andremovecablefromcabinet.
5.Installo-ring(406)onnewtransducer(405).
6.Installtransducerinmanifold.Markendofcable
withtape(red=transducerA,blue=transducerB).
7.Routenewcableintocabinetandthreadinto
bundleasbefore.Attachcabletiestobundle
asbefore.
8.ConnectAsidepressuretransducercable
toHCMport#6.ConnectBsidepressure
transducercabletoHCMport#7.