EasyManua.ls Logo

Graco RoadLazer RoadPak - Page 25

Graco RoadLazer RoadPak
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
3A5384B 25
4. Fill fuel tank.
5. Check hydraulic oil level. Add only synthetic
Hydraulic Oil, ISO 46 with a viscosity index (VI) of
154 or higher. Hydraulic tank capacity is approxi-
mately 4.0 gallons (15.14 liters) for RoadPak mod-
els and approximately 8.0 gallons (30.28 liters) for
RoadPak HD models.
6. Check oil level in compressor. NOTE: If red dot is
visible, add SAE 30W non-detergent air compressor
oil.
7. Verify all hose/fitting connections are tight.
8. Turn paint pump hydraulic valves to OFF (closed)
position, and bypass valve to START position.
9. Turn valve lever by guns clockwise 1/4 turn to OFF
position.
10. Place suction tube and drain tube in grounded metal
pail partially filled with flushing fluid. Attach ground
wire to pail and to earth ground.
11. Turn prime/spray valve down.
12. Install clean inlet strainer.
NOTE: There must be a minimum of 0.5 in. between
bottom of strainer and suction tube.
Safe Range (cold)
ti5243a
ti16789a
ti15953a
ti16547a
ti16552a
ti16553a
0.5 in.

Other manuals for Graco RoadLazer RoadPak