EasyManua.ls Logo

Graco ULTRA 500 - Page 30

Graco ULTRA 500
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WARNING
Before doing this procedure, follow the Pressure
the
risk
of
serious bodily injury, including fluid in-
Relief Procedure Warning on page
2
to
reduce
jection or splashing in the eyes or on the skin, or
injury from moving part.
NOTE
See
Fig.
26
except where noted.
1.
Disconnect the pump outlet hose
(23)
from the
displacement pump outlet nippie
(22).
2.
Remove the pressure control cover and screws.
Disconnect the four motor leads.
See
the
WIRING
DIAGRAM
below. Remove the conduit seal
(31)
from the conduit connector
(345)
coming
Into
the
control box.
3.
Use an adjustable wrench to loosen the conduit
connector
(345)
at the pressure control assembly
(40).
4.
Swing the conduit
(41)
away from theconduit
connector.
5.
Pull the motor leads through the elbow, one at a.
time.
CAUTION
Always pull the motor leads one at a time to avoid
loosening the terminals.
6.
Loosen the conduit connector
(39)
at the motor
.
and pull the conduit
(41)
away from the motor,
then
pull
the leads through the conduit, one at a
time.
7.
Unscrew the conduit connector
(39)
from the
motor.
8.
Pull the wires through the elbow, one at a time.
9.
Remove the front cover, screws, and washers
(11,13,3).
IO.
Remove the motor cover
(1)
and screws
(16.12)
and spacers
(15).
11.
Remove the three screws
(8)
and washers
(7)
from
of
the drive housing
(two
screws are
recessed and one is behind.the pump
displacement rod
-
see
Fig.
23
on page
28).
12.
Remove the
two
screws
(58)
and washers
(7)
from the top of the motor.
I
1