FIRMWARE 1.0.4.4 GXW42XX USER MANUAL PAGE 36 OF 57
Choose “Yes” to enable automatic upgrade and provisioning. When set to No, GXW42XX will
only do upgrade once at boot up.
When “Check every day” or “Check every week” is checked, user can specify “Hour of the day (0-
23)” or “Day of the week (0-6)”. Default time is Monday 1AM.
If set to Yes, configuration file is authenticated before being accepted. This protects the
configuration from unauthorized modifications.
For firmware encryption. It should be 32-digit in Hexadecimal Representation. End user should
keep it blank.
By default, HTTP uses port 80. This field is for customizable web port.
If set to Yes, telnet access will be disabled. Default is No.
Set new password for web GUI access as User. This field is case sensitive with a maximum
length of 30 characters.
Set new password for web GUI access as Admin. This field is case sensitive with a maximum
length of 30 characters.
URL of the TR-069 Auto Configuration Servers (e.g., http://acs.mycompany.com, or IP address).
User specify the ACS Username
User specify the ACS password
Default is No. If set to YES, device will send inform packets to the ACS
Frequency that the inform packets will be sent out to the ACS
Connection
Request
Username
The user name for the TR-069 Auto Configuration Server to connect to the phone.
Connection
Request
Password
The password for the TR-069 Auto Configuration Server to connect to the phone.