UCM6300 Series/UCM6300 Audio Series:
High Availability User Guide
P a g e | 15
HA CONFIGURATION PARAMETERS
Table 2: HA Related Parameters
Force to switch the roles of
active UCM and standby
UCM.
Caution: Please do not use this
function unless necessary (e.g.,
it can be used during firmware
upgrading).
Configure the HA station
type for the UCM.
In HA setup, one UCM must be
primary and the other one must
be secondary.
This is the IP address for
the active UCM in service.
This IP address is shared by the
primary and secondary UCM.
The UCM in active status
providing PBX service will
always be using this IP address
regardless it’s the primary or
\secondary UCM. This IP
address can only be used for the
active UCM.
This is the IP address of
the peer UCM in HA setup.
This is the static IP address of
the peer UCM in HA setup
connected via heartbeat port.
This is the MAC address
of the peer UCM in HA
setup.
This is the MAC address of the
peer UCM in HA setup
connected via heartbeat port.
This is the port used for
communication between
the two UCM via heartbeat
port.
It is recommended to use default
port.