114
All Long wash tank filling
time
The level sensor in the
wash tank has not been
activated within 20
minutes of the solenoid
valve opening.
Check the water supply to the machine,
as well as the rinse pump. Clean the
rinse nozzles. Check the sensitivity of
level sensors
115
All Long rinse tank filling
time
The level sensor in the
rinse tank has not been
activated within 5
minutes of the solenoid
valve opening.
Check the water supply to the machine,
as well as the solenoid valve for rinse
tank filling. Check the condition
(sensitivity value) of level sensors in the
rinse tank.
116
All Low water level,
problem with foam
Foam forming in the
machine.
Avoid using detergent designed for
washing up by hand. Change the wash
water. Contact your detergent supplier if
you still the problems with foam
formation persist.
117
All Long rinse time
The lower level sensor
in the rinse tank has not
indicated that the correct
amount of water has
been pumped out.
Check rinse pump function. Clean the
rinse nozzles, and check if faulty signal
from lower level sensor in rinse tank.
118
All Drain valve not closed The drain valve has
opened during an active
process in the machine.
Close the drain valve.
119
Gastro
Flexi
Motor circuit breaker for
wash pump tripped
The motor is overloaded
The impeller is blocked
by granules or by small
utensils
Check if the impeller turns free, reset
the motor circuit breaker, start the
machine and check the current of all
three phases. Check the volume of
charged granules.
120 Gastro
Combi
Basket drive device
blocked
The basket is prevented
from rotating, utensils
outside of the basket.
Check if all wash gods are loaded
properly in the basket, reload I
necessary. Check the magnetic
proximity switch and two magnets on
the connection block. Check the fuse F4
on the PCB.
121 Gastro
Combi
Motor circuit breaker for
the booster pump
tripped
The motor is overloaded Check if the impeller turns free, reset
the motor circuit breaker, start the
machine and check the current of all
three fazes.
122 Gastro
Combi
Incorrect downwards
hood movement
The hood has not
reached down within 25
seconds; the security
switch has not changed
its status.
Check the solenoid valve for lowering
of the hood.
Check the condition of the hydraulic
cylinder.