Settings and Measurement
Switching displays
Analog and logic/pulse can be switched as shown below.
Analog settings
When you use CH ALL to set an input range and filter, all channels are set to the same settings if the input is
the same. Range is set only for the same input CHs.
Span All Settings, is set only for the same range CHs.
CAUTION
ALL and Span All Settings are set only for the currently displayed group (per 10 channels).
Input .................................... Selects input condition.
Off : No signal input is accepted.
Voltage : Used for measuring direct-current voltage.
Temperature : Used for measuring temperature.
Humidity : Used for measuring humidity.
Range ................................. Specifies the range of signal input to be measured.
Voltage : 20, 50, 100, 200, 500mV, 1, 2, 5, 10, 20, 50, 1-5V
Temperature : TC-K, TC-J, TC-T, TC-R, TC-E, TC-B, TC-S, TC-N,
TC-W, PT100, JPT100, PT1000
Available SPAN Settings
<Voltage Ranges>
・Display Logic/Pulse Data
・Display Analog Data
Range Maximum SPAN Minimum SPAN Minimum Resolution
20mV -22.000 to +22.000mV 0.200mV 0.001mV
50mV -55.00 to +55.00mV 0.50mV 0.01mV
100mV -110.00 to +110.00mV 1.00mV 0.01mV
200mV -220.00 to +220.00mV 2.00mV 0.01mV
500mV -550.0 to +550.0mV 5.0mV 0.1mV
1V -1.1000 to +1.1000V 0.0100V 0.0001V
2V -2.2000 to +2.2000V 0.0200V 0.0001V
5V -5.500 to +5.500V 0.050V 0.001V
10V -11.000 to +11.000V 0.100V 0.001V
20V -22.000 to +22.000V 0.200V 0.001V
50V -55.00 to +55.00V 0.50V 0.01V
1-5V -5.500 to +5.500V 0.050V 0.001V