GREE GMV5 INDOOR UNIT SERVICE MANUAL
110
to ensure proper use.
Please contact the local Gree appointed service center before installation. Any
malfunctioncaused by the unit that is not installed by the Gree appointed service center would
probably not be dealt with on time because of the inconvenience of the business contact.
It should be guided under the professional personnel when the air conditioner unit is moved to
other place.
3.9.4 Selection of air switch and power cord
Model
Power Cord Size
Air Switch apacity
(A)
Minimum Sectional
Area of Ground Wire
(mm
2
/AWG)
Minimum Sectional
Area of Power Cord
(mm
2
/AWG)
GMV-NX140P/A(X1.2)-K
220-240V~50Hz
6
1.0/AWG18
1.0/AWG18
GMV-NX224P/A(X2.0)-M
380-415V 3N~50Hz
6
1.0/AWG18
1.0/AWG18
GMV-NX280P/A(X2.5)-M
380-415V 3N~50Hz
6
1.0/AWG18
1.0/AWG18
GMV-NX280P/A(X3.0)-M
380-415V 3N~50Hz
6
1.0/AWG18
1.0/AWG18
GMV-NX450P/A(X4.0)-M
380-415V 3N~50Hz
6
1.0/AWG18
1.0/AWG18
GMV-NDX125P/A-T
220-240V 1Ph 50Hz
208-230V 1Ph 60Hz
6
1.0/AWG18
1.0/AWG18
GMV-NDX140P/A-T
220-240V 1Ph 50Hz
208-230V 1Ph 60Hz
6
1.0/AWG18
1.0/AWG18
GMV-NDX224P/A-T
220-240V 1Ph 50Hz
208-230V 1Ph 60Hz
10
1.0/AWG18
1.0/AWG18
GMV-NDX250P/A-T
220-240V 1Ph 50Hz
208-230V 1Ph 60Hz
10
1.0/AWG18
1.0/AWG18
GMV-NDX280P/A-T
220-240V 1Ph 50Hz
208-230V 1Ph 60Hz
10
1.0/AWG18
1.0/AWG18