Super Free Match
Service Manual
CONTROL
39
(display "
" signal) and Quiet OFF (there is no signal of "
"displayed),after powered on, the Quiet OFF is
defaulted.
Note: the Quiet function cannot be set up in Fan and Dry mode; Under the Quiet mode
(Display "
" Under the Quiet mode (Display "
" signal), the fan speed is not available.
12) CLOCK :
Press CLOCK button, blinking
. Within 5 seconds, pressing + or - button adjusts the present time.
Holding down either button above 2 seconds increases or decreases the time by 1 minute every 0.5 second and
then by 10 minutes every 0.5 second. During blinking after setting, press CLOCK button again to confirm the
setting, and then
will be constantly displayed.
13) T-ON/ T-OFF:
Press T-ON button to initiate the auto-ON timer. To cancel the auto-timer program, simply press this button
again.
After press of this button,
disappears and "ON "blinks. 00:00 is displayed for ON time setting. Within
5 seconds, press + or - button to adjust the time value. Every press of either button changes the time setting by 1
minute. Holding down either button rapidly changes the time setting by 1 minute and then 10 minutes. Within 5
Seconds after setting, press TIMER ON button to confirm.
Press T-OFF button to initiate the auto-off timer. To cancel the auto-timer program, simply press the button
again. TIMER OFF setting is the same as TIMER ON.
14) TURBO:
Press this button to activate / deactivate the Turbo function which enables the unit to reach the preset
temperature in the shortest time. In COOL mode, the unit will blow strong cooling air at super high fan speed. In
HEAT mode, the unit will blow strong heating air at super high fan speed.
15) LIGHT:
Press LIGHT button to turn on the display's light and press this button again to turn off the display's light. If
the light is turned on,
is displayed. If the light is turned off, disappears.
16) X-FAN:
Pressing X-FAN button in COOL or DRY mode, the icon
is displayed and the indoor fan will continue
operation for 10 minutes in order to dry the indoor unit even though you have turned off the unit. After
energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
3.3.2 Guide for General Operation
1) Combination of "+"and "-" buttons: About lock
Press "+" and "-" buttons simultaneously to lock or unlock the keypad. If the remote controller is locked,
is displayed. In this case, pressing any button blinks three times.
2) Combination of "MODE " and "-" buttons :
About switch between Fahrenheit and centigrade At unit OFF, press "MODE" and "-" buttons
simultaneously to switch between and .