43
Level of Air
setting
1 2 3 4 5 6 7 8 9 10
Opening time
of fresh air
valve
60
/6
60
/12
60
/18
60
/24
60
/30
60
/36
60
/42
60
/48
60
/54
Always on
NOTE:
time indicated in the table: unit’s operating time (min) / opening time of
fresh air valve per operating time (min).
5.10 Save Setting
Save Function: Air conditioner can be operated in small
temperature range by setting the minimum temperature under
Cooling and Dry modes and setting maximum temperature under
Heating, 3D Heating and Space Heating modes. Thus, energy
saving can be realized.
Start up Save function for Cooling: When the unit is off,
simultaneously press “TIMER” and “+” buttons for 5s, the buzzer will
give out a sound and then unit will enter into Save setting mode. “
icon is blinking. Mode icon is on. Press “MODE” button to switch to
Cooling or Dry mode. Press “+” or “-” button to adjust the
temperature limit for Save function; press “ENTER” button to start up
Save function.