Wired Controller XK46
25
Parame
ter
code
Parameter name
Parameter
range
Defa
ult
valu
e
Note
P46
Clear Filter Clean
accumulated time
00: do not clear
01: clear
00
--
P49
Opening angle of
indoor unit air-return
plate*
01: angle 1(25°)
02: angle 2(30°)
03: angle 3(35°)
01
Only applicable to units with
air-return plate
P50
Air outlet
temperature setting
for Fresh Air Indoor
Unit in cooling*
16°C~30°C(61°F
~
86°F )
18°C
(6
F)
Only applicable to Fresh Air Indoor
Unit
P51
Air outlet
temperature setting
for Fresh Air Indoor
Unit in heating*
16°C~30°C(61°F
~
86°F )
22°C
(71°
F)
Only applicable to Fresh Air Indoor
Unit
P54
Union setting of
Fresh Air Indoor
Unit*
00: without union
control
01: with union
control
00
After union function is set, Fresh Air
Indoor Unit will be turned on/off
following the on/off status of common
indoor unit. Besides, Fresh Air Indoor
Unit can also be turned on/off
manually.
Note: only applicable to Fresh Air
Indoor Unit.