Greenline 33 99
AC Error 2 listing (HEX field):
Error Name
HEX
Code
DEC
Code
AC response
Reason
Remedy
Note
No error
0x0000
/
/
/
/
Over current
0x0001
17
Power reduction
Phase current above 150A
Check load
1
Motor
overheat
0x0002
18
Power reduction
Measured motor temperature
above 115°C
Reduce load, el.
motor cooling
required
HCU
overheat
0x0004
19
Power reduction
HCU temperature
above 85°C
Reduce load, HCU
cooling required
High bat.
current
0x0008
20
Power reduction
Calculated battery current
above max level
Reduce load
2
High ph.
current
0x0010
21
Power reduction
Phase current
above max level
Reduce load
2
High elect.
power
0x0020
22
Power reduction
Calculated electrical power
above max level
Reduce load
2
High mech.
power
0x0040
23
Power reduction
Calculated mechanical power
above max level
Reduce load
2
/
0x0080
24
Charging
level invalid
0x0100
25
Neutral mode /
Charging
interrupted
Battery voltage do not follow
charger predefined level
Wait for battery
voltage drop
Charging
voltage high
0x0200
26
Neutral mode /
Charging
interrupted
Battery voltage in
generator mode above 53,4 V
Wait for battery
voltage drop
Bat. volt.
prop. min
0x0400
27
Neutral mode /
El. prop. interrupted
Battery voltage in electric
propulsion mode below 42 V
Recharge battery
DC-link volt.
prop. min
0x0800
28
Neutral mode /
El. prop. interrupted
DC-link voltage in electric
propulsion mode below min
level
Recharge battery /
Reduce load
3
DC-link volt.
prop. max
0x1000
29
Neutral mode /
El. prop. interrupted
DC-link voltage in electric
propulsion mode above max
level
Wait for DC-link
voltage-drop
3