41
Procedure in case of fire in the chimney:
1. Close the door, the ash drawer, and the ue damper (if available).
2. Call the local re department.
3. Do not aempt to exnguish the re with water.
4. Aer an ignion of soot, a specialist shall check the heater and the chimney for the
possibility of further operaon.
IMPORTANT! The use of cleaning log (briquees), homemade compounds creang high
temperature in the heater rebox and chimney, is prohibited for the purposes of burning
the soot deposited in them.
The stones deteriorate with me as the heater is operated, this is why it is necessary to
turn them over and reposion in the stone heater at least once a year, when the heater is
frequently operated. Remove the destroyed stones and their parts from the stone heater,
replace them with new ones. Before laying the stones, clean the heater with a wet cloth.
The ash drawer shall be cleaned at all mes before heang, so that the combuson air
passing through the ash drawer to cool the grate, thereby increasing its service life. If there
is a thermal glass door, use so cleaning waste with special agents for cleaning heat-
resistant glass of replaces and heaters in accordance with the applicaon instrucons.
Please, obey re safety rules!
2.9. Typical faults and troubleshooting methods
1) Fault: Odors appear during the heater operaon.
Possible cause:
• There is leover industrial oil on the heater surface, or/and the odor comes from heat-
resistant enamel.
• When heang up, the heater can enhance the odors present in the air, even if their
source is not the sauna itself or the sauna heater. Such sources, for example, can be
surfaces treated with paint, oil, glue and other materials.
Troubleshoong methods:
• Stoke the heater in accordance with paragraph 2.3.
• Select appropriate materials for treatment of the surfaces in the sauna; use them in
accordance with the applicaon instrucons.
2) Fault: The sauna room is not heang up.
Possible cause:
• The sauna room is too large for the heang capacity of the heater.
• Thermal insulaon of the room is not in compliance with the requirements.
• Insucient chimney dra.
• Low quality or wet combuson material.
• Blockage in the chimney or ue channels of the heater.
Troubleshoong methods:
• Check that the heater capacity matches the size of the sauna (secon 1).
• Check the thermal insulaon of the room (secon 1).
• Check combuson material for compliance (paragraph 2.4).
• Perform maintenance (paragraph 2.8).
3) Fault: The stones in the stone heater do not heat up.
Possible cause:
• The sauna room is too small for the heang capacity of the heater. The room is heang
up faster than the stones.