-14-
Model G0705 (Mfg. since 09/09)
Neutral
Hot
Ground
110 VAC
5-20 Plug
(As Recommended)
Hot
Hot
Ground
6-15 Plug
(As Recommended)
G
PE
V2
V1
U2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
U2
V1
V2
Z1
W1
Z2
W2
U1
To Electrical Box
Start
Capacitor
150 MFD
250 VAC
Run
Capacitor
20 MFD
450 VAC
110V Terminal
Block Jumper
Position.
(Wire positions
are the same for
110V/220V)
To Electrical Box
Cord Rewired for 110V
Figure 10. Cord rewired for 110V.
11. Use a Phillips screwdriver to remove the
screws that secure the two metal jumpers
to the terminal block, as shown in Figure 9,
then remove both jumpers. Be careful not to
mix up the locations of any of the wires while
you do so.
Figure 9. Changing motor jumper positions.
14. Install a NEMA 5-20 plug such as the one
shown in Figure 3 onto the power cord, as
illustrated in Figure 10. Refer to SECTION
8: WIRING starting on Page 45 for detailed
wiring diagrams.
12. Place both of the jumpers into the 110V loca-
tion shown in Figure 8.
13. Replace the screws you removed in Step
11, making sure all wires are secured in the
same positions they were originally in, as
shown in Figure 8. Refer to SECTION 8:
WIRING starting on Page 45 for detailed wir-
ing diagrams.