Note: When the battery type set to Li, the setting option 12, 13, 21 will change to display percent.
Note: When the battery type set as LI”, the Maximum charge current can't be modified by the user. When the
communication fail, the inverter will cut off output.
Note: Any questions about communicating with BMS, please consult with Growatt.
3. Communicating with battery BMS in parallel system
If need to use communicate with BMS in a parallel system, you should make sure to connect the BMS communication
cable between the battery and one inverter of the parallel system. Its recommended to connect to the master
inverter of the parallel system.
12
Setting SOC point back to utility
source when selecting “SBU
priority” or “Solar first” in program
01
Default 50%, 6%~95% Settable
13
Setting SOC point back to battery
mode when selecting “SBU
priority” or “Solar first” in program
01
Default 95%, 10%~100% Settable
21
Low DC Cut-off SOC.
If self-defined is selected in
program 5, this program can be
set up
Default 20%, 5%~50% Settable

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF 3000TL LVM and is the answer not in the manual?

Growatt SPF 3000TL LVM Specifications

General IconGeneral
ModelSPF 3000TL LVM
Rated Power3000W
Input Voltage230 VAC
Output Voltage230 VAC
Battery Voltage24 VDC
Max PV Input Voltage145VDC
Max Charging Current80A
Peak Efficiency93%
Output Frequency50 Hz/60 Hz
Dimensions330 x 485 x 135 mm
Battery TypeLead-acid or Lithium
CommunicationRS232
MPPT Voltage Range30-115VDC