LCD Setting
After pressing and holding ENTER button for 3 seconds, it will enter setting mode. Press “UP” or “DOWN” button
to select setting programs. Then press “ENTER” button to confirm the selection or ESC button to exit.
Setting Programs:
Program
Description
Setting Option
01
Output source priority: To
configure load power source
priority
Solar first
Solar energy provides power to the loads as first priority.
If solar energy is not sufficient to power all connected loads, battery
energy will supply power the loads at the same time.
Utility provides power to the loads only when any one condition
happens:
-
Solar energy is not available
-
Battery voltage drops to either low-level warning voltage or the setting
point in program 12.
Utility first (default)
Utility will provide power to the loads as first priority.
Solar and battery energy will provide power to the loads only when
utility power is not available.
SBU priority
Solar energy provides power to the loads as first priority.
If solar energy is not sufficient to power all connected loads, battery
energy will supply power to the loads at the same time.
Utility provides power to the loads only when battery voltage drops to
either low-level warning voltage or the setting point in program 12.
02
Maximum charging current: To
configure total charging current
for solar and utility chargers.
(Max. charging current = utility
charging current + solar
charging current)
24V model: default 60A, 10A~140A settable
48V model: default 60A, 10A~120A settable
(If Li is selected in Program 5, this program cant be set up)
03
AC input voltage range
Appliance (default)
If selected, acceptable AC input voltage range
will be within 65~140VAC
If selected, acceptable AC input voltage range
will be within 95~140VAC
(Only diesel generators
allowed)
If selected, acceptable AC input voltage range
will be within 65~140VAC. In this mode, the
Max. charging current is 30A.
Note: When connecting generator, the
generator should be no less than 10KVA(no
less than 20KVA for three phase parallel
system), and the inverters should be no more
than 2 units in one phase.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF 3000TL LVM and is the answer not in the manual?

Growatt SPF 3000TL LVM Specifications

General IconGeneral
ModelSPF 3000TL LVM
Rated Power3000W
Input Voltage230 VAC
Output Voltage230 VAC
Battery Voltage24 VDC
Max PV Input Voltage145VDC
Max Charging Current80A
Peak Efficiency93%
Output Frequency50 Hz/60 Hz
Dimensions330 x 485 x 135 mm
Battery TypeLead-acid or Lithium
CommunicationRS232
MPPT Voltage Range30-115VDC