Power saving mode
enable/disable
Saving mode disable (default)
If disabled, no matter connected load is low or high, the on/off status of
inverter output will not be effected.
Saving mode enable
If enabled, the output of inverter will be off when connected load is pretty
low or not detected.
Lithium (only suitable when communicated with BMS)
User-Defined
If “User-Defined” is selected, battery charge voltage and low DC cut-off
voltage can be set up in program 19, 20 and 21.
Auto restart when
overload occurs
Restart disable (default)
Auto restart when over
temperature occurs
Restart disable (default)
Number of series
batteries connected
(e.g. Showing batteries are connected in 4 series)
Maximum utility
charging current
Note: If setting value in
Program 02 is smaller
than that in Program 11,
the inverter will apply
charging current from
Program 02 for utility
charger
48V model: default 30A, 10A~80A Settable
(If Li is selected in program 5, this program can’t be set up)