EasyManuals Logo

Growatt SPF 5000TL HVM-WPV User Manual

Growatt SPF 5000TL HVM-WPV
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
17
12
Setting voltage point
back to utility source
when selecting “SBU
priority” or “Solar first
in program 01
48V model: default 46.0V, 44.0V~51.2V Settable
13
Setting voltage point
back to battery mode
when selecting “SBU
priority” or “Solar first
in program 01
48V model: default 54.0V, 48.0V~58.0V Settable
14
Charger source priority:
To configure charger
source priority
If this off grid solar inverter is working in Line, Standby or Fault mode, charger
source can be programmed as below:
Solar first
Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar and Utility
Solar energy and utility will both
charge battery.
Only Solar
Solar energy will be the only charger
source no matter utility is available
or not.
If this off grid solar inverter is working in Battery mode or Power saving mode,
only solar energy can charge battery. Solar energy will charge battery if it's
available and sufficient.
15
Alarm control
Alarm on (default)
Alarm off
16
Backlight control
Backlight on (default)
Backlight off
17
Beeps while primary
source is interrupted
Alarm on (default)
Alarm off
18
Overload bypass:
When enabled, the unit
will transfer to line
mode if overload occurs
in battery mode.
Bypass disable (default)
Bypass enable
19
Bulk charging voltage
(C.V voltage). If self-
defined is selected in
program 5, this program
can be set up
48V model: default 56.4V, 48.0V~58.4V Settable

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF 5000TL HVM-WPV and is the answer not in the manual?

Growatt SPF 5000TL HVM-WPV Specifications

General IconGeneral
ModelSPF 5000TL HVM-WPV
CategoryInverter
Rated Power5000W
Max PV Input Power6000W
Number of MPPT Trackers2
AC Output Voltage230V
AC Output Frequency50/60Hz
Battery Voltage48V
Max Charging Current100A
Max Discharging Current100A
Protection DegreeIP20
Cooling MethodFan Cooling
Peak Efficiency93%
Max PV Input Voltage450V
CommunicationUSB
Operating Temperature Range-10°C to +50°C
Dimensions330 x 485 x 135 mm

Related product manuals