Page #12 background imageLoading...
Page #12 background image
10
PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and
PV modules.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It'‟ very important for system safety and efficient operation to use appropriate cable for PV module
connection. To reduce risk of injury, please use the proper recommended cable size as below.
Model
Typical Amperage
Cable Size
Torque
4KW/5KW/6KW
80A
8AWG
1.6~1.8 Nm
8KW/10KW/12KW
120A
8AWG
1.6~1.8 Nm
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
1.
Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
2.
Open circuit Voltage (Voc) of PV modules should be higher than min. batteryvoltage.
Solar Charging Mode
INVERTER MODEL
SPF 4-12000T DVM
SPF 4-12000T DVM-MPV
Max. PV Array Open Circuit Voltage
150Vdc
250Vdc
PV Array MPPT Voltage Range
60~145Vdc
60~245Vdc
Please follow below steps to implement PV module connection:
1.
Remove insulation sleeve 10 mm for positive and negativeconductors.
2.
Check correct polarity of connection cable from PV modules and PV input
connectors. Then, connect positive pole (+) of connection cable topositive pole
(+) of PV input connector. Connect negative pole (-) of connection cable to
negative pole (-) of PV inputconnector.
3.
Make sure the wires are securely connected.
PV Wiring
4KW/5KW/6KWMPPT 80A
8KW/10KW/12KW, MPPT 120A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF 6000T DVM-MPV and is the answer not in the manual?

Growatt SPF 6000T DVM-MPV Specifications

General IconGeneral
ModelSPF 6000T DVM-MPV
CategoryInverter
Rated Power6000W
Output Voltage230V AC
Efficiency93%
MPPT Voltage Range120-450V
Max. Charging Current120A
Output Frequency50/60 Hz
Battery Voltage48V
Max PV Charging Current120A
Operating Temperature-10°C to 50°C
CommunicationUSB
Max Solar Input Voltage500V
ProtectionOverload, Short circuit, Over-temperature
DC Voltage48V
AC Voltage230VAC
Cooling MethodFan