27
Fault Reference Code
Fault Code
Fault Event
Icon on
01
Fan is not working.
02
Over temperature
03
Battery voltage is too high
05
Output short circuited
06
Output voltage is abnormal.
Output voltage is too high.
07
Overload time out
20
BMS communication loss
51
Over current or surge
Warning Indicator
Warning
Code
Warning Event
Audible Alarm
Icon flashing
01
MPPT PCB Fan Abnormal
Beep twice every second
03
High Battery Voltage
Beep twice every second
04
Battery low voltage/
Battery SOC low
Beep twice every second
07
Overload In Inverter Mode
Beep twice every second
12
Solar controller over
temperature
Beep once every second
51
Solar Charger Over Current
Beep once every second
54
PV input over voltage
Beep once every second
58
AC output low voltage
Beep once every second

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF 6000T DVM-MPV and is the answer not in the manual?

Growatt SPF 6000T DVM-MPV Specifications

General IconGeneral
ModelSPF 6000T DVM-MPV
CategoryInverter
Rated Power6000W
Output Voltage230V AC
Efficiency93%
MPPT Voltage Range120-450V
Max. Charging Current120A
Output Frequency50/60 Hz
Battery Voltage48V
Max PV Charging Current120A
Operating Temperature-10°C to 50°C
CommunicationUSB
Max Solar Input Voltage500V
ProtectionOverload, Short circuit, Over-temperature
DC Voltage48V
AC Voltage230VAC