17
In battery mode, it will present battery capacity.
Load Percentage
Battery Voltage
LCD Display
Load >50%
< 1.717V/cell
1.717V/cell ~ 1.8V/cell
1.8 ~ 1.883V/cell
> 1.883 V/cell
50%> Load > 20%
< 1.817V/cell
1.817V/cell ~ 1.9V/cell
1.9 ~ 1.983V/cell
> 1.983
Load < 20%
< 1.867V/cell
1.867V/cell ~ 1.95V/cell
1.95 ~ 2.033V/cell
> 2.033
Load Information
Indicates overload.
Indicates the load level by 0-24%, 25-49%, 50-74% and 75-100%.
0%~24%
25%~49%
50%~74%
75%~100%
Mode Operation Information
Indicates unit connects to the mains.
Indicates unit connects to the PV panel.
Indicates load is supplied by utility power.
Indicates the utility charger circuit is working.
Indicates the DC/AC inverter circuit is working.
These three sins indicate the output priority. SOL.FIRST indicates solar first.
BAT.FIRST indicates battery first. UTI.FIRST indicates utility first.
Mute Operation
Indicates unit alarm is disabled.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF 6000T DVM-MPV and is the answer not in the manual?

Growatt SPF 6000T DVM-MPV Specifications

General IconGeneral
ModelSPF 6000T DVM-MPV
CategoryInverter
Rated Power6000W
Output Voltage230V AC
Efficiency93%
MPPT Voltage Range120-450V
Max. Charging Current120A
Output Frequency50/60 Hz
Battery Voltage48V
Max PV Charging Current120A
Operating Temperature-10°C to 50°C
CommunicationUSB
Max Solar Input Voltage500V
ProtectionOverload, Short circuit, Over-temperature
DC Voltage48V
AC Voltage230VAC
Cooling MethodFan