EasyManuals Logo

Growatt SPF 6000T DVM-MPV User Manual

Growatt SPF 6000T DVM-MPV
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
21
15
Alarm control
Alarm on (default)
Alarm off
16
Backlight control
Backlight on (default)
Backlight off
17
Beeps while primary
source is interrupted
Alarm on (default)
Alarm off
19
C.V. charging voltage
If self-defined is
selected in program 5,
this program can be set
up
48V model: default 56.4V, 48.0V~58.4V Settable
20
Floating charging
voltage.
If self-defined is
selected in program 5,
this program can be set
up
48V model: default 54.0V, 48.0V~58.4V Settable
21
Low DC cut-off voltage.
If self-defined is
selected in program 5,
this program can be
set up
48V model: default 42.0V, 40.0V~48.0V Settable
48 model Lithium mode: default 20%, 5%~50% Settable
22
RS485
communication address
Default 001,001-255 Settable
23
Battery equalization
Disabled (Default)
Enable
If Flooded or User-Defined is selected in program this
program can be set up.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Growatt SPF 6000T DVM-MPV and is the answer not in the manual?

Growatt SPF 6000T DVM-MPV Specifications

General IconGeneral
ModelSPF 6000T DVM-MPV
CategoryInverter
Rated Power6000W
Output Voltage230V AC
Efficiency93%
MPPT Voltage Range120-450V
Max. Charging Current120A
Output Frequency50/60 Hz
Battery Voltage48V
Max PV Charging Current120A
Operating Temperature-10°C to 50°C
CommunicationUSB
Max Solar Input Voltage500V
ProtectionOverload, Short circuit, Over-temperature
DC Voltage48V
AC Voltage230VAC
Cooling MethodFan