11.1 The pump is not running and there is no indicator
light
Cause
TM053827
Power supply failure.
Remedy
Check if the power supply is switched off. Switch on the
power supply.
Check if the external motor protection has tripped.
Check cables and cable connections for defects and loose
connections.
11.2 The pump rotates backwards
No light indication in Grundfos Eye.
TM053827
Cause
Foot valve or non-return valve is clogged or defective.
Foot valve or non-return valve is locked in an open position.
Remedy
Remove and clean, repair, or replace the valve
11.3 The pump can be reset but runs only for a few
seconds
Alarm.
Motor is stopped.
Two opposite red indicator lights flashing simultaneously.
TM053839
Cause
The pump inlet pressure is too low.
The inlet pipe is partly blocked by impurities.
The non-return valve is blocked in a closed position.
There is a leakage in the inlet pipe.
There is air in the inlet pipe or pump.
Remedy
Check the inlet conditions of the pump.
Remove and clean the inlet pipe.
Inspect, repair, or replace the non-return valve if necessary.
Vent the inlet pipe and the pump.
11.4
The performance is unstable and there is a green
indicator light
TM053831
Cause
The pump inlet pressure is too low.
The inlet pipe is partly blocked by impurities.
There is a leakage in the inlet pipe.
There is air in the inlet pipe.
Remedy
Check the inlet conditions of the pump.
Remove and clean the inlet pipe.
Remove and repair the inlet pipe.
Vent the inlet pipe and the pump.
11.5 The pump is not running and the motor shows a
red indicator light
TM053839
Cause
The motor is overheated.
Remedy
Check the inlet conditions of the pump.
Remove and clean the inlet pipe.
Remove and repair the inlet pipe.
Vent the inlet pipe and the pump.
Cause
The sensor is defective.
Remedy
Replace the sensor.
Cause
Cause unknown.
Remedy
Contact Grundfos or an authorized service workshop.
17
English (US)

Table of Contents

Other manuals for Grundfos CMBE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos CMBE and is the answer not in the manual?

Grundfos CMBE Specifications

General IconGeneral
Flow RateUp to 6 m³/h
MaterialStainless Steel
Motor TypePermanent magnet motor
Liquid Temperature0°C to +60°C
Maximum Operating Pressure10 bar
Enclosure ClassIP55
Frequency50 / 60 Hz
Pump TypeCentrifugal pump
Power Supply1 x 200-240 V
ControlIntegrated Frequency Converter
Max Head60 m
Seal TypeMechanical seal
Motor Power0.3 - 1.5 kW