Cause Remedy
Yes
The internal non-return valve
is defective or blocked in
completely or partially open
position.
Small leakage is detected by
the anti-cycling function.
Alarm is on.
Clean, repair or replace the
non-return valve.
Check the taps and reconsider
the usage pattern, e.g. ice
machines, water evaporators
for air-conditioning, etc.
- No
The shaft seal is seized up.
The pump is blocked by
impurities.
See section 10. Starting up the
product after the standstill.
No No
Overheating due to seized-
up or choked-up pump.
Contact your pump supplier.
No No
Too low or too high supply
voltage.
Check the supply voltage and
correct the fault, if possible.
No -
The pump has been stopped
by external input or calendar
function.
15.4 The pump is running
Grundfos Eye Indicator light
Automatic
reset
Cause Remedy
No
The non-return valve is not
properly closed, or the pipe
system is leaking. This
happens when cycling alarm
and/or leakage alarm are
disabled.
Check and repair the pipe
system, or clean, repair or
replace the non-return valve.
No
Small continuous
consumption.
Check the taps and reconsider
the usage pattern (ice
machines, water evaporators
for air-conditioning, etc.).
29
English (GB)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos SCALA1 5-55 and is the answer not in the manual?

Grundfos SCALA1 5-55 Specifications

General IconGeneral
Product NameGrundfos SCALA1 5-55
CategoryWater Pump
Max Head55 m
Max Flow Rate5 m³/h
Inlet/Outlet Size1"
System Pressure10 bar
Enclosure ClassIPX4D
Pumped LiquidClean water
Frequency50/60 Hz
Max Pressure10 bar
Motor TypePermanent Magnet Motor
Protection ClassX4D
Liquid Temperature0°C to 45°C
Inlet Pressure6 bar
ApprovalsCE, EAC