15.6 The pump performance is insufficient
Grundfos Eye
Indicator
light
Automatic
reset
Cause Remedy
- - Pump inlet pressure is too low. Check pump inlet conditions.
- - Pump is undersized.
Replace the pump with a
larger pump.
- -
Inlet pipe, inlet strainer or
pump are partially blocked by
impurities.
Clean the inlet pipe or the
pump.
- - Leakage in the inlet pipe. Repair the inlet pipe.
- -
Air in the inlet pipe or the
pump.
Prime the inlet pipe and the
pump. Check pump inlet
conditions.
15.7 The pump starts and stops too
frequently
Grundfos Eye
Indicator
light
Automatic
reset
Cause Remedy
- -
Leakage in suction pipe or
air in the water.
Restore the water supply or
repair suction pipe.
- -
A tap has not been closed
entirely after use.
Check that all taps have been
closed. See section Anti-
cycling.
- -
Minor leakage in the
system.
Check the system for leakages.
See section Anti-cycling.