PNEG-750-G2 16" Series II Sweep 131' and 135' Diameter 63
8. Shut Down
Normal Shut Down
A. Before shutting down the unit, be sure the sumps and unload conveyor are empty.
B. Press the “Stop” button on the control panel.
Emergency Shut Down
A. Know how to shut down the auger in case of an emergency.
B. Step off the foot switch and press the “Stop” button.
C. Disconnect and lock out the power source.
Storage Preparation
A. Be sure the sumps and unload conveyor are empty.
B. Close the sump control gates.
C. Park the sweep behind the intermediate sumps, so that the sumps are on the auger side of
the sweep.
D. Shut down the auger.
E. Make sure all fasteners are tight.
F. After allowing the motors to cool down, cover the motors with the tarps supplied with the sweep.
G. Place blocks under the frame of the sweep to help support the sweep during storage.
NEVER start the equipment under load. Doing so may cause damage. This type of
damage is considered a misuse of the equipment. Any misuse of the equipment
may void the warranty.