EasyManua.ls Logo

Guardall Pi-8 - 11 User Programmable Functions; Chime Mode; How to Program the Chime Mode; Programming the Part Set (at Home) Mode

Guardall Pi-8
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
11. USER PROGRAMMABLE FUNCTIONS
11.1 CHIME MODE
The chime mode allows you to monitor certain nominated circuits when the panel is unset.
The keypad buzzer and the internal alarm speaker (if fitted) will beep rapidly for a short
period if a chime circuit is alarmed - the sounder will not sound.
11.1.1 HOW TO PROGRAM THE CHIME MODE
1. Hold the 2 key down for two seconds.
2. The buzzer will sound briefly and the READY and TAMPER leds will flash
on/off together to show that the panel is in the (chime) programming mode.
3. To select any circuit for CHIME, press the key corresponding to that circuit.
The circuit led will be on constantly.
4. To de-select a circuit, press the corresponding key again. The circuit led will
extinguish.
5. Press the # key to exit the chime programming mode. (If no key is pressed for
60 seconds the chime mode will be exited automatically).
Note: To de-select a chime circuit, repeat the above steps and make sure that the
circuit led is off.
11.2 PROGRAMMING THE PART SET (AT HOME) MODE
11.2.1 PART SET CIRCUITS
PART SET circuits are those that are bypassed automatically when the panel is
PART SET. In the PART SET mode, you will remain at home while the panel is set.
To avoid triggering the alarm circuits, such as the bedrooms or other areas which
require access, they must be bypassed. This is done automatically when you set,
but you need to program these circuits (once only) before you use the PART SET
mode.

Table of Contents