13
11.4 ADDING OR CHANGING USER CODES
This can only be done by the Master User.
11.4.1 ENTERING NEW AND CHANGING OLD CODES
The PI-8 Alarm Panel has 16 programmable user codes:
CODE 1 The master user code.
CODES 2 to 15 General user codes.
CODE 16 Duress code.
To enter a new code or change an existing code:
1. Ensure that the panel is unset.
2. Hold the * key down for two seconds (until the keypad “beeps”).
3. The READY and TAMPER LEDs will flash alternately, indicating that the panel
is now ready to program user codes.
4. Enter the master user code (code 1) and then the * key. (The default master
user code is 1234).
5. The READY and TAMPER LEDs will now flash on and off together indicating
that the correct master code was entered. If the wrong code is entered, the
keypad will beep three times.
6. Enter the number (1 to 16) of the user code which you wish to enter or change
and press the * key.
7. Now enter the new code (4 digits) and press the * key. The keypad will give a
long beep to indicate the entry of a valid code.
8. Repeat steps 6 to 8 if you wish to enter or change other user codes.
9. Once all of the user codes have been programmed, press the # key to exit.
Note: All codes must be 4 digits long.
To clear a user code, follow steps 1 - 6 above, but instead of entering a 4 digit code
at step 7, press the * key. That particular user code will be deleted.