16
13. TROUBLE CONDITIONS
In the event of a trouble condition occurring, the POWER LED will flash on and off. To
determine what has happened, press and hold the 7 key for 2 seconds and check the
entries in the table below for permanently on circuit LEDs. The ready, tamper and power
LEDs will also flash.
LED TROUBLE CONDITION
3 Mains power failure.
4 Low battery.
14. TEST MODE
Hold down the 8 for 2 seconds key to enter this mode. (Only the Power LED will be lit).
While in the test mode the alarming of any circuit will cause the keypad and the internal
speaker to beep.
Press the following keys to test the various aspects of the system.
KEY
ACTION
1 Sounder test (half a second).
2 Keypad buzzer and speaker test.
3 Strobe test (short flash).
4 Pulses all three auxiliary outputs.
Press the # key to exit this mode, otherwise it will time out after twenty seconds.
NOTE: If a problem exists with the panel, please contact your
installation company.