PX Control Panel User Manual – Issue C
- 28 -
User Authority Menu
Schedule 1-2 (PX18/34)
On/Off
A user can be programmed with schedules 1 and/or 2 to control access times. The timer and holiday
schedules may also be programmed.
User Authority Menu
Set Group 1-max
On/Off
If the Set Group option is on the user can be programmed any combination of set groups.
User Authority Menu
Door 1-2 (PX18/34)
On/Off
If access modules are fitted to the system then a user can be authorised for access through doors 1
and/or 2.
User Menu
Schedule (PX80/500)
Code-5
A user can be programmed with a schedule to control access times. Program 0 to allow 24hr access.
User Menu
Door Access (PX80/500)
Code-5
Each user can be programmed for any combination of the available doors.
User Options
User-nnnn nnnn=User number
Enable-Off On/Off, this option must be on to view other options
Door 1-Off On/Off
. . .
Door 32-Off On/Off
Challenged-Off On/Off
Door Options
Challenged
On/Off
If a user is programmed as challenged then the door release and open times will be automatically
doubled for the user.
User Menu
Lockout (PX80/500)
Code-6
A user can be locked out of the system at any time. All user configuration is retained while a user is
locked out.
User-nnnn The user number
Lockout-Off On/Off
User Menu
Expiry Date (PX80/500)
Code-7
Expiry dates can now be programmed for all users (panel and access). This option is available even if no
access module is fitted to the system.
Expiry Date