Enters: Sets the NoGo condition to 
when the input signal stays within 
the limit boundary. 
2.  Press When again to change the 
menu to Violating. Use the Variable 
knob to choose the action for when 
a violation occurs. 
Stop: The waveform will be frozen. 
Stop_Beep: The waveform will be 
frozen and a beep will be output. 
Continue: Ignore the violation. 
Continue_Beep: Output a beep, but 
continue to monitor the signal. 
1.  Press Compare Source from the 
bottom menu and use the Variable 
knob to select the source.  
1.  To set a tolerance, press Compare 
Source again to toggle the menu to 
Auto Tolerance. Use the Variable 
knob to choose the tolerance as a 
percentage. 
If a tolerance is set, the maximum 
and minimum boundary is reset as 
the tolerance boundary.