PSW Series User Manual 
136 
Remote Monitoring 
The PSW power supplies have remote monitoring support for 
current and voltage output. They also support monitoring of 
operation and alarm status.  
 
  External monitoring of output voltage and current → from page 
136 
  External monitoring of operation mode and alarm status → from 
page 138 
External Voltage and Current Monitoring 
 
The MIL 26 pin connector is used to monitor 
the current (IMON) or voltage (VMON) output.  
An output of 0~10V represents the voltage or 
current output of 0~ rated current/voltage 
output. 
  IMON =  (current output/full scale) × 10 
  VMON =  (voltage output/full scale) × 10 
External voltage and current monitoring 
doesn’t need to be enabled in the configuration 
settings.   
 